The common faults and solutions of micro centrifugal pumps are as follows:
Startup failure
– Motor does not rotate :
– Cause : Matching switch, DC power supply failure; Insufficient battery or battery power; Poor line contact; Poor contact between motor and carbon brush.
– Solution : Check the switch, voltage regulator power supply, if there is a problem in time to replace or repair; Charging or replacing batteries or batteries; Inspect the line, repair or replace the damaged line; Clean the carbon brush or adjust the carbon brush contact with the motor.
– Motor work but not water :
– Reason : There are debris or particle impurities in the pump; Suction higher than pump rated suction.
– Solution : disassemble the pump body and clean up debris; Reduce the suction height so that the suction is within the rated range.
Traffic problem
– Insufficient flow :
– Reason : The actual lift of the pump exceeds the allowable lift; The voltage is too low, the motor speed is slow; Suction range is too high; There’s air coming in from the pipe.
– Solution : Replace the pump with the appropriate head; Check the power supply voltage, use a voltage regulator or adjust the power supply line; Reduce suction; Drain the air in the pipe and check the tightness of the pipe.
– Flow becomes smaller :
– Reason : The water inlet is blocked by impurities; The filter is used for a long time and is blocked by particle impurities.
– Solution : Clean up impurities at the inlet; Clean or replace the filter.
Running fault
– Abnormal water outage :
– Reason : Motor does not start, there is a circuit fault; The pipeline is blocked; Pipeline rupture; Blockage of the water filter network; The suction pipe is above the water surface.
– Solution : Check the circuit, troubleshoot; Clean up blockages; Repair welding or replace the broken pipeline; Clean up the water filtration network; Adjust the suction pipe to ensure that it is below the surface of the water.
– Intense vibration or abnormal increase in noise :
– Reason : The access voltage is higher than the set voltage; Installation Angle is not fixed; Motor or pump shaft is bent.
– Solution : Use suitable voltage regulator equipment to stabilize voltage; Fixed installation Angle to ensure firm installation; Check motor and pump shafts and correct or replace bent parts.
Other glitches
– Seal leakage :
– Reason : Packing seal or mechanical seal is damaged.
– Solution : Adjust or replace the filler; Check and replace mechanical seals.
– Bearing temperature is too high :
– Reason : insufficient lubrication; Bearing wear; Overload operation.
– Solution : Check and add lubricant; Replace worn bearings; Adjust operating load to avoid overload.